ELECTROHYDRAULIC UNIT FOR DOOR AND DOCK LEVELLER

Home » HYDRAULIC CONSOLLE » ELECTROHYDRAULIC UNIT FOR DOOR AND DOCK LEVELLER
ELECTROHYDRAULIC UNIT FOR DOOR AND DOCK LEVELLER

ELECTROHYDRAULIC UNIT FOR DOOR AND DOCK LEVELLER

Electrohydraulic unit for lifting the FIDELITY system sectional doors and for operating a dock leveller. Easy and safe inspections of the unit, wall mounted.

Standard pressure set at works, 150 bars. For the heaviest doors the pressure can be set at the installation up to 200 bars. The dock levellers normally demand 130 bars.

The Campisa electrohydraulic Consolle is an electrohydraulic powerpack that supplies oil in pressure and that contains the distributing system of it.
The buttons on the commands are:

  • lifting and lowering of the sectional door that can be “dead man”, semiautomatic or automatic
  • actioning of the dock leveller: see section “dock levellers” Link

The type of the Consolle to be installed follows the needs of the installation. For the loading bays it is suggested to install automatic-up and “dead man” down doors, as to be sure of having always the door totally open when loading.

GENERAL CHARACTERISTICS

Electrohydraulic Consolle: IP 54 unit inclusive of commands protection IP 56, wall mounted.

EMERGENCY OPENING

The Consolle for the sectional door has an hydraulic hand pump for the emergency opening.
Emergency opening (patented) also by battery drilling machine with hexagon inside the hexagon screw on the head of the electric motor. See details of power required

MULTIFUNCTIONALITY

In case of dock leveller and door on the same loading bay one Consolle only can be installed to serve the two elements, with big saving also of the installation times.

FINISHING

The cover of the Consolle is made og sendzimir galvanized steel sheet, lacquered Simil RAL 9002

COMMAND

Feeding safety switch, transformer for the feeding of the coils of the hydraulic valves

Special steel sheet for the installation of the Consolle onto insulated panels by 4 rivets only..
Stand-alone support, from ground

EN 1398 – Dock leveller – safety requirements
EN 13241 – Sectional doors
Machine Directive
Maximum pressure valve.
Thermal sensor o the windings of the motor.

The standard nominal load of the dock levellers is of 6.000 kg (10.000 kg uniformly distributed, but this is not the scope of the dock levellers), optional 9.000 kg (15.000 kg uniformly distributed).

Click here to identify the product code and its dimensions
Tension 230-400 V threephased
Power 0,75 kW or optional 1,1 kW
Frequence 50/60 Hz

DOWNLOAD LOADING BAYS CATALOGUE

DOWNLOAD

REQUEST QUOTE FOR CAMPISA’S PRODUCTS

CONTACT US

SEE OTHER PRODUCTS OF THE SECTION HYDRAULIC CONSOLLE

Electrohydraulic unit

Dock leveller “in pit” electrohydraulic units